{"id":190,"date":"2023-04-25T06:00:00","date_gmt":"2023-04-25T06:00:00","guid":{"rendered":"https:\/\/mthpumps.com\/blog\/?p=190"},"modified":"2024-08-27T09:48:05","modified_gmt":"2024-08-27T14:48:05","slug":"jockey-pump-selection-for-fire-suppression-systems","status":"publish","type":"post","link":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/","title":{"rendered":"Jockey Pump Selection for Fire Suppression Systems"},"content":{"rendered":"\n<p class=\"\"><a href=\"https:\/\/www.mthpumps.com\/applications\/jockey.html\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"150\" class=\"wp-image-191\" style=\"width: 300px;\" src=\"https:\/\/i0.wp.com\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/Jockey.png?resize=300%2C150&#038;ssl=1\" alt=\"MTH Pumps for Fire Jockey Systems\"><\/a>Automatic fire suppression systems normally utilize two pumps. One unit is the main fire pump which delivers large volumes of water to the fire suppression system (sprinklers) in case of fire. When there is no fire, a low flow, high head \u201c<a href=\"https:\/\/www.mthpumps.com\/applications\/jockey.html\">Jockey Pump<\/a>\u201d is used to overcome the normal system plumbing leakage that bleeds down system pressure over time, and maintains a consistent system pressure. When the system bleeds enough pressure to trigger the jockey pump, it cycles on and re-pressurizes the system back to its normal level. When a large enough pressure drop occurs that the jockey pump cannot overcome it (such as a fire opening a sprinkler head or a fire hose being turned on), the main high volume fire pump starts and takes over the water supply duties. Utilizing the main fire pump for the re-pressurizing function would be very expensive and limit the life of the pump and motor due to the numerous starts &amp; stops. A variety of different MTH turbines are used as fire system jockey pumps depending upon system size. See our Jockey Pump Selection Chart at <a href=\"https:\/\/www.mthpumps.com\/applications\/jockey.html\">https:\/\/www.mthpumps.com\/applications\/jockey.html<\/a> to find the right size pump for your system.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Automatic fire suppression systems normally utilize two pumps. One unit is the main fire pump which delivers large volumes of water to the fire suppression system (sprinklers) in case of fire. When there is no fire, a low flow, high head \u201cJockey Pump\u201d is used to overcome the normal system plumbing leakage that bleeds down [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"nf_dc_page":"","om_disable_all_campaigns":false,"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[8],"tags":[],"class_list":["post-190","post","type-post","status-publish","format-standard","hentry","category-regenerative-turbine-pump-tuesday"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Jockey Pump Selection for Fire Suppression Systems - MTH Pumps<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Jockey Pump Selection for Fire Suppression Systems - MTH Pumps\" \/>\n<meta property=\"og:description\" content=\"Automatic fire suppression systems normally utilize two pumps. One unit is the main fire pump which delivers large volumes of water to the fire suppression system (sprinklers) in case of fire. When there is no fire, a low flow, high head \u201cJockey Pump\u201d is used to overcome the normal system plumbing leakage that bleeds down [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/\" \/>\n<meta property=\"og:site_name\" content=\"MTH Pumps\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/mthpumps\" \/>\n<meta property=\"article:published_time\" content=\"2023-04-25T06:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-08-27T14:48:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/Jockey.png\" \/>\n<meta name=\"author\" content=\"Scott Carlson\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@mthpumps\" \/>\n<meta name=\"twitter:site\" content=\"@mthpumps\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Scott Carlson\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/\"},\"author\":{\"name\":\"Scott Carlson\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#\\\/schema\\\/person\\\/849ad835a26816115b4357629147827b\"},\"headline\":\"Jockey Pump Selection for Fire Suppression Systems\",\"datePublished\":\"2023-04-25T06:00:00+00:00\",\"dateModified\":\"2024-08-27T14:48:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/\"},\"wordCount\":207,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/Jockey.png\",\"articleSection\":[\"Regenerative Turbine Pump Tuesday\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/\",\"url\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/\",\"name\":\"Jockey Pump Selection for Fire Suppression Systems - MTH Pumps\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/Jockey.png\",\"datePublished\":\"2023-04-25T06:00:00+00:00\",\"dateModified\":\"2024-08-27T14:48:05+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/mthpumps.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/Jockey.png?fit=300%2C150&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/mthpumps.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/Jockey.png?fit=300%2C150&ssl=1\",\"width\":300,\"height\":150,\"caption\":\"MTH T51 Series Pump Installed in a Commercial Building\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/2023\\\/04\\\/25\\\/jockey-pump-selection-for-fire-suppression-systems\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Jockey Pump Selection for Fire Suppression Systems\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/\",\"name\":\"MTH Pumps\",\"description\":\"Each week, we want to highlight one of the many applications that you can find a regenerative turbine pump, along with some of the wisdom needed to make the most out of your regenerative turbine pump.\",\"publisher\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#organization\",\"name\":\"MTH Pumps\",\"url\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/mthpumps.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/MTH-Logo.png?fit=300%2C133&ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/mthpumps.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/MTH-Logo.png?fit=300%2C133&ssl=1\",\"width\":300,\"height\":133,\"caption\":\"MTH Pumps\"},\"image\":{\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/mthpumps\",\"https:\\\/\\\/x.com\\\/mthpumps\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/mthpumps\",\"https:\\\/\\\/www.instagram.com\\\/mth_pumps\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/#\\\/schema\\\/person\\\/849ad835a26816115b4357629147827b\",\"name\":\"Scott Carlson\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6a557d10109c01228b48fc994d555a54b8acc6c8bd985372f140fde65ed11765?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6a557d10109c01228b48fc994d555a54b8acc6c8bd985372f140fde65ed11765?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6a557d10109c01228b48fc994d555a54b8acc6c8bd985372f140fde65ed11765?s=96&d=mm&r=g\",\"caption\":\"Scott Carlson\"},\"sameAs\":[\"https:\\\/\\\/mthpumps.com\\\/blog\"],\"url\":\"https:\\\/\\\/mthpumps.com\\\/blog\\\/author\\\/administrator\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Jockey Pump Selection for Fire Suppression Systems - MTH Pumps","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/","og_locale":"en_US","og_type":"article","og_title":"Jockey Pump Selection for Fire Suppression Systems - MTH Pumps","og_description":"Automatic fire suppression systems normally utilize two pumps. One unit is the main fire pump which delivers large volumes of water to the fire suppression system (sprinklers) in case of fire. When there is no fire, a low flow, high head \u201cJockey Pump\u201d is used to overcome the normal system plumbing leakage that bleeds down [&hellip;]","og_url":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/","og_site_name":"MTH Pumps","article_publisher":"https:\/\/www.facebook.com\/mthpumps","article_published_time":"2023-04-25T06:00:00+00:00","article_modified_time":"2024-08-27T14:48:05+00:00","og_image":[{"url":"https:\/\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/Jockey.png","type":"","width":"","height":""}],"author":"Scott Carlson","twitter_card":"summary_large_image","twitter_creator":"@mthpumps","twitter_site":"@mthpumps","twitter_misc":{"Written by":"Scott Carlson","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/#article","isPartOf":{"@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/"},"author":{"name":"Scott Carlson","@id":"https:\/\/mthpumps.com\/blog\/#\/schema\/person\/849ad835a26816115b4357629147827b"},"headline":"Jockey Pump Selection for Fire Suppression Systems","datePublished":"2023-04-25T06:00:00+00:00","dateModified":"2024-08-27T14:48:05+00:00","mainEntityOfPage":{"@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/"},"wordCount":207,"commentCount":0,"publisher":{"@id":"https:\/\/mthpumps.com\/blog\/#organization"},"image":{"@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/#primaryimage"},"thumbnailUrl":"https:\/\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/Jockey.png","articleSection":["Regenerative Turbine Pump Tuesday"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/","url":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/","name":"Jockey Pump Selection for Fire Suppression Systems - MTH Pumps","isPartOf":{"@id":"https:\/\/mthpumps.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/#primaryimage"},"image":{"@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/#primaryimage"},"thumbnailUrl":"https:\/\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/Jockey.png","datePublished":"2023-04-25T06:00:00+00:00","dateModified":"2024-08-27T14:48:05+00:00","breadcrumb":{"@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/#primaryimage","url":"https:\/\/i0.wp.com\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/Jockey.png?fit=300%2C150&ssl=1","contentUrl":"https:\/\/i0.wp.com\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/Jockey.png?fit=300%2C150&ssl=1","width":300,"height":150,"caption":"MTH T51 Series Pump Installed in a Commercial Building"},{"@type":"BreadcrumbList","@id":"https:\/\/mthpumps.com\/blog\/2023\/04\/25\/jockey-pump-selection-for-fire-suppression-systems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/mthpumps.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Jockey Pump Selection for Fire Suppression Systems"}]},{"@type":"WebSite","@id":"https:\/\/mthpumps.com\/blog\/#website","url":"https:\/\/mthpumps.com\/blog\/","name":"MTH Pumps","description":"Each week, we want to highlight one of the many applications that you can find a regenerative turbine pump, along with some of the wisdom needed to make the most out of your regenerative turbine pump.","publisher":{"@id":"https:\/\/mthpumps.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/mthpumps.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/mthpumps.com\/blog\/#organization","name":"MTH Pumps","url":"https:\/\/mthpumps.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/mthpumps.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/MTH-Logo.png?fit=300%2C133&ssl=1","contentUrl":"https:\/\/i0.wp.com\/mthpumps.com\/blog\/wp-content\/uploads\/2024\/08\/MTH-Logo.png?fit=300%2C133&ssl=1","width":300,"height":133,"caption":"MTH Pumps"},"image":{"@id":"https:\/\/mthpumps.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/mthpumps","https:\/\/x.com\/mthpumps","https:\/\/www.linkedin.com\/company\/mthpumps","https:\/\/www.instagram.com\/mth_pumps\/"]},{"@type":"Person","@id":"https:\/\/mthpumps.com\/blog\/#\/schema\/person\/849ad835a26816115b4357629147827b","name":"Scott Carlson","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6a557d10109c01228b48fc994d555a54b8acc6c8bd985372f140fde65ed11765?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6a557d10109c01228b48fc994d555a54b8acc6c8bd985372f140fde65ed11765?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6a557d10109c01228b48fc994d555a54b8acc6c8bd985372f140fde65ed11765?s=96&d=mm&r=g","caption":"Scott Carlson"},"sameAs":["https:\/\/mthpumps.com\/blog"],"url":"https:\/\/mthpumps.com\/blog\/author\/administrator\/"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/posts\/190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/comments?post=190"}],"version-history":[{"count":1,"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/posts\/190\/revisions"}],"predecessor-version":[{"id":192,"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/posts\/190\/revisions\/192"}],"wp:attachment":[{"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/media?parent=190"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/categories?post=190"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mthpumps.com\/blog\/wp-json\/wp\/v2\/tags?post=190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}