150 • 160 • 170 Series |
|
The contractor shall furnish (and install as shown on
the plans) an MTH Turboflex regenerative type pump model_________ size______
of (BRONZE FITTED) (BRONZE RING) (ALL IRON) (ALL BRONZE) (316 STAINLESS
STEEL) construction. Each pump shall have a capacity of ____GPM when operating
at a total head of _______feet at the specified temperature, viscosity,
specific gravity, and with _______feet NPSHA. The maximum speed shall
not exceed 1750 RPM. Pump shall be of the vertically split case design
with removable bearing housings and is to be furnished with mechanical
seals. The channel rings shall be replaceable external type. The suction
connection shall be _____” NPT located in the top vertical position
and be cast separately from the discharge. The discharge shall be ______”
NPT in the top horizontal position and the pump shall be self-venting.
The impeller(s) shall be located on a stainless steel shaft between sealed
grease lubricated ball bearings. The impeller(s) shall be hydraulically
self positioning with no external adjustment necessary. Each pump shall
be tested at the specified capacity and head prior to shipment. The pump
shall be mounted on a steel baseplate, flexibly coupled with aluminum
guard to a ___HP ____phase _____Hertz ______volt _____RPM horizontal (DRIP-PROOF)
(TOTALY ENCLOSED) (EXPLOSION PROOF) motor. The motor is to be sized to
prevent overloading at the highest head condition listed in the specification. |
|