MTH Pumps – Application Limitations & Operating Ranges
To ensure the proper selection, performance, and longevity of MTH Pumps products, please review the following maximum operating parameters. Applications exceeding these limitations may require consultation with MTH engineering for custom solutions or special materials.
General Performance Limits (Standard Product Ranges)
| Parameter | Typical Range | Notes |
|---|---|---|
| Maximum Temperature | 250°F (121°C) | May vary by model and material; consult factory for higher temp options. |
| Minimum Temperature | -20°F (-29°C) | Lower limits may require special seals and materials. |
| Maximum Inlet Pressure | 150 PSI (10.3 bar) | Inlet pressures above this require special configurations. |
| Maximum Discharge Pressure | 400 PSI (27.6 bar) | Depends on pump model and stage count. |
| Maximum Differential Pressure | 350 PSI (24.1 bar) | Typical for multi-stage regenerative turbine models. |
| Maximum Flow Rate | 60 GPM (13.6 m³/h) | Varies by model; MDT, T31, and specially configured units. |
| Maximum Viscosity | 150 SSU (~32 cSt) | Higher viscosity fluids reduce performance; not ideal for viscous media. |
| Maximum Specific Gravity | 1.2 | Heavier fluids may require derating or custom builds. |
| Maximum Suction Lift | 20 ft (6 m) when flooded or primed | Not self-priming; positive suction head recommended. |
| Minimum Flow Rate | ~0.5 GPM (1.9 L/min) | Continuous low flow can lead to overheating; consult curve for each model. |
Electrical and Motor Compatibility
| Parameter | Specification | Notes |
|---|---|---|
| Voltage Options | 115V, 208-230V, 460V, 575V (1ø & 3ø) | Standard NEMA configurations; IEC options available. |
| Motor Enclosures | TEFC, ODP, Explosion Proof, Washdown Duty | Application-specific; explosion-proof not standard. |
| Frequency | 50/60 Hz | Check for performance de-rating on 50Hz systems. |
| Motor HP | 1/3 thru 15 HP (close-coupled)up to 60 (flex-coupled | Larger motors available by special request. |
Fluid Compatibility Considerations
| Fluid Type | Limitation |
|---|---|
| Abrasive Fluids | Not recommended without custom wear-resistant components. |
| Slurries/Solids | Not suitable for fluids with solids > 100 microns or > 1% by volume. |
| Corrosive Fluids | Limited by material selection; 316SS, Bronze, or Alloy 20 options help. |
| High Vapor Pressure | Can cause cavitation; consult factory for solutions. |
| Flammable Fluids | Explosion-proof motors and seal isolation required. |
Additional Design & Environmental Limits
| Parameter | Specification |
|---|---|
| Installation Orientation | Horizontal standard; vertical mount may need custom bearing support. |
| Ambient Temperature Range | -20°F to 120°F (-29°C to 49°C) |
| Noise Level | ≤ 80 dBA typical |
| Altitude Limit | Up to 6,000 ft (1,830 m) without derating |
Important Notes
-
Custom Solutions Available: MTH Pumps offers custom-engineered configurations for applications outside the limits listed above.
-
Always Refer to Individual Pump Curves: This page provides general parameters. Performance limits can vary significantly across product lines (e.g., T31 vs. E51 vs. MDT).
-
Consult MTH Engineering: For borderline or critical applications, contact our applications team to confirm compatibility.